KelvinPlanHow much light each room needs, and what colour it should be.

Lighting a 12 × 18 ft basement

Total light needed
6,480lumens
216 ft² × 30 foot-candles
Room area216ft²
Target light levelIES guidance for a basement30foot-candles
Total lumens6,480lm
Colour temperatureraise it if the ceiling is low and dark4000K
Bulbs (800 lm each)9bulbs
Recessed cans (4 ft spacing)463 lm each14fixtures
Room
basement
Width
12 ft
Length
18 ft

Where 6,480 lumens comes from

Lighting is specified in foot-candles — lumens landing on each square foot of the surface you care about. A basement is worked to 30 foot-candles. Across 216 ft² that is 6,480 lumens in total.

Split it up

One fixture putting out 6,480 lumens and 14 fixtures adding up to the same number light a room very differently. A single source throws hard shadows and glare; several spread the light and make the room feel larger. Aim for layers — ambient, task, and something low for the evening.

Colour temperature

4000K suits this room. Warmer light reads as relaxed and is what you want where people wind down; cooler light keeps edges and colours crisp, which matters where there is work to do.

Notes

  • Foot-candles are lumens per square foot at the work surface. Ceilings above 9 ft, dark walls or dark flooring all eat light — add roughly 10% per extra foot of ceiling height.
  • Spread the total across several fixtures rather than one bright source. One 6,480 lm fixture and 14 smaller ones add up the same but look completely different.