KelvinPlanHow much light each room needs, and what color it should be.

Room Lighting Calculators

Lumens and color temperature by room type and size, from the light levels lighting designers actually work to.

Lighting a room is two decisions that get conflated: how much light, and what color it is. They are independent, and getting the second one wrong is what makes a correctly lit room feel wrong.

How much

Light level is measured in footcandles, and the targets come from IES recommendations for living spaces. A living room wants about 15. A kitchen wants 35 for general light. A home office wants 40. A garage used as a workshop wants 50.

Multiply by floor area and you have the lumens the room needs. That is the number to shop by — not watts, which stopped meaning anything useful when LEDs arrived.

What color

Color temperature is measured in kelvin, and lower is warmer. 2700K is the color of an incandescent bulb and reads as relaxed. 3000K is slightly crisper and is the usual choice for kitchens and bathrooms. 4000K reads as neutral daylight and belongs in workshops and garages, not living rooms.

The mistake is mixing them in one sightline. A 2700K lamp beside a 4000K downlight makes both look wrong, and no amount of brightness fixes it.

General light is not task light

A kitchen at 35 footcandles of ceiling light still has bad countertops, because the person standing at the counter is between the light and the work. Under-cabinet lighting is not decorative — it is the only light in the room that reaches the cutting board.

The same applies to bathroom mirrors: light from directly above casts shadows into every feature of a face. Light from the sides is what a mirror actually needs.

Put it on a dimmer

It costs almost nothing at install and it is the difference between a room that works at dinner and one that works at eleven at night. Retrofitting it means opening walls.

What the calculator assumes

Any lumen figure is an answer to a question with hidden conditions in it. These are the ones behind the number this calculator returns.

An 8 ft ceiling. Light weakens with distance, so a taller room needs more of it to put the same amount on the floor. Add roughly 10% per extra foot.

Mid-tone surfaces. A white room recycles light and needs about 15% less; a room with dark walls and a dark floor needs about 30% more. Those two corrections stack, and a dark room with a 10 ft ceiling wants over one and a half times the table figure.

After dark, with no daylight. Every figure here is the artificial-light requirement. A room with a large window needs the same fittings and will use them for fewer hours.

An empty room. Furniture absorbs light. A room with a dark sofa, a rug and full-length curtains reads dimmer than the arithmetic suggests.

General lighting only. Task areas — a worktop, a desk, a mirror — are a separate calculation on top, not a share of this one.

Turning a total into fittings

The calculator gives a number of lumens for the room. Converting that into things you can buy is the step where rooms go wrong, and there is one rule that matters more than the rest.

Divide it across at least three sources. A 2,500 lumen living room done as one 2,500 lumen ceiling fitting produces a bright spot, dark corners, and hard shadows on every face in the room. The same 2,500 lumens as a ceiling fitting, two table lamps and a floor lamp produces a room.

More sources at lower output is better in every domestic space. The single exception is a workshop or garage, where even shadow-free light from a few large fittings is exactly what you want.

Then check what each fitting actually delivers. The lumen figure on a box is the bare lamp. A lined fabric shade passes perhaps 60% of it; an enclosed opal globe around 70%; a recessed downlight 80–90%. A room specified on box figures and built with shaded lamps will land well under target.

A worked example, end to end

A 13 × 17 ft living room with a 9 ft ceiling, mid-tone walls, dark wood floor.

Step Working Result
Floor area 13 × 17 221 ft²
Target living room, 15 fc 3,315 lm
Ceiling correction 9 ft → ×1.10 3,647 lm
Surface correction dark floor → ×1.15 4,194 lm
Fitting losses shaded lamps → ÷0.75 ≈ 5,600 lm to buy

Split across four sources — a ceiling fitting and three lamps — that is roughly 1,400 lumens each, which is a 100 W-equivalent LED in each. All of it on dimmers, because that figure is the daytime requirement and the room will run at a fraction of it in the evening.

The arithmetic looks laborious written out and takes about a minute in practice. What it prevents is the far more common approach — buying one bright ceiling fitting and wondering why the room feels like a corridor.

3 articles

How many lumens for a 18 × 18 ft dining room?

Total light needed
6,480lumens
324 ft² × 20 foot-candles
dining room · 18×18 ft18 ft18 ft6,480 lumens total · about 9 fixtures · 2700K
Room area324ft²
Target light levelIES guidance for a dining room20foot-candles
Total lumens6,480lm
Colour temperaturedimmable, centred on the table2700K
Bulbs (800 lm each)9bulbs
Recessed cans (4 ft spacing)309 lm each21fixtures

Notes

  • Foot-candles are lumens per square foot at the work surface. Ceilings above 9 ft, dark walls or dark flooring all eat light — add roughly 10% per extra foot of ceiling height.
  • Spread the total across several fixtures rather than one bright source. One 6,480 lm fixture and 21 smaller ones add up the same but look completely different.

Open the full page for this calculation →

Lighting for a room

660 calculations · browse all